Ultrapol RG 03/10 system requires meeting of processing conditions listed below in order to obtain a foam of parameters accordant with a declaration of performance (Deklaracji Właściwości Użytkowych, DWU) and of an appropriate capacity
Room temperature : min 20 oC
Substrate temperature: min 20 oC
Raw materials temperature: 25-30 oC
Temperature „on blocks” 50-55 oC
Temperature „on the hose” 55-60 oC
Pressure 100-130 atm
Humidity of boards and rafters below 20%
Ingredient A requires only slight mixing before spraying and regulation of temperature to the required value. During work, only mixing is required in order to stabilise temperature.
The table contains technical data regarding Ultrapol RG 03/10 foam. More detailed information and full documentation is available in “download” tab
Essential characteristics |
Performance |
Technical specification |
Reaction to fire |
E class |
PN-EN 14315-1:2013-06 PN-EN 13501-1+A1:2010 PN-EN 11925-2:2010 |
Heat conductivity |
λm = 0.037 W/mK λ90.90 = 0.038 W/mK |
PN-EN 14315-1:2013-06 PN-EN 12667:2002 |
Declared value of the heat conductivity factor, taking into account the aging effect, λD for each thickness of insulation
|
λD = 0.039 W/mK |
PN-EN 14315-1:2013-06
|
Momentary absorbability of water at partial immersion |
Wp < 0.3 kg/m2 |
PN-EN 14315-1:2013-06 PN-EN 1609:2013-07 met. B |
Water vapour permeability: water vapour diffusion resistance factor water vapour permeability factor |
µ > 3.6 >0.147 mg/(m·h·Pa) |
PN-EN 14315-1:2013-06 PN-EN 12086:2013-07 |
Stability of dimension in temp. 70oC and 90% of relative humidity, after 48h |
Δε < 1% |
PN-EN 14315-1:2013-06 PN-EN 1604:2013-07 |
Stability of dimensions in temp. -20oC after 48h |
Δε < 0.5% |
PN-EN 14315-1:2013-06 PN-EN 1604:2013-07 |
Volatile organic compound emissions |
Complies with requirements in the scope of national regulations regarding secretion of hazardous substances and may be used in A and B category rooms intended for people. |
PN-EN 14315-1:2013-06 PN-EN ISO 16000-9:2009 ISO 16000-6:2011 PB’LS-002/4/09-1999 PB’LS-012/2/09-2004 |