Conditions for processing and parameters of Ultrapol RG 03/10 foam

Ultrapol RG 03/10 system requires meeting of processing conditions listed below in order to obtain a foam of parameters accordant with a declaration of performance (Deklaracji Właściwości Użytkowych, DWU) and of an appropriate capacity 

Room temperature :                           min 20 oC

Substrate temperature:                       min 20 oC

Raw materials temperature:               25-30 oC

Temperature „on blocks”                   50-55 oC

Temperature „on the hose”                55-60 oC

Pressure                                              100-130 atm

Humidity of boards and rafters          below 20%

 

Ingredient A requires only slight mixing before spraying and regulation of temperature to the required value. During work, only mixing is required in order to stabilise temperature. 

The table contains technical data regarding Ultrapol RG 03/10 foam. More detailed information and full documentation is available in “download” tab

 

  

 Essential characteristics

 Performance

 Technical specification

 Reaction to fire

 E class

 PN-EN 14315-1:2013-06

 PN-EN 13501-1+A1:2010

 PN-EN 11925-2:2010

 Heat conductivity

 λm = 0.037 W/mK

 λ90.90 = 0.038 W/mK

 PN-EN 14315-1:2013-06

 PN-EN 12667:2002

 Declared value of the heat conductivity factor, taking into account the aging effect, λD for each thickness of insulation

 

 λD = 0.039 W/mK

 PN-EN 14315-1:2013-06

 

 Momentary absorbability of water at partial immersion

 Wp < 0.3 kg/m2

 PN-EN 14315-1:2013-06

 PN-EN 1609:2013-07 met. B

 Water vapour permeability:

 water vapour diffusion resistance factor

 water vapour permeability factor

 µ > 3.6

 >0.147 mg/(m·h·Pa)

 PN-EN 14315-1:2013-06

 PN-EN 12086:2013-07

 Stability of dimension in temp. 70oC and 90% of

 relative humidity, after 48h

 Δε < 1%

 PN-EN 14315-1:2013-06

 PN-EN 1604:2013-07

 Stability of dimensions in temp. -20oC after 48h

 Δε < 0.5%

 PN-EN 14315-1:2013-06

 PN-EN 1604:2013-07

 Volatile organic compound emissions

 Complies with requirements in the scope of national regulations regarding secretion of hazardous substances and may be used in A and B category rooms intended for people.

 PN-EN 14315-1:2013-06

 PN-EN ISO 16000-9:2009

 ISO 16000-6:2011

 PB’LS-002/4/09-1999

 PB’LS-012/2/09-2004

Ask us a question

If you have any questions, please use the contact form. We will try to send a reply within 24 hours about the received inquiry.

logo Office Ultrapur
phone number
+48 61 415 29 82

biuro@ultrapur.pl
Write how we can help
First name
Phone number
E-mail adress
Enter the code
*The data entered in the contact form will be processed in order to answer the question sent. More information in the Privacy Policy.